7.3 Automatic mode
The device is operated in automatic mode (activated automatic starting function) as follows:
 Fig. 3 Control elements/ports on page EN-10
If the welding process is interrupted, automated cleaning of the filter membranes occurs after a run-on time
of 20 seconds.
The filter membranes must be cleaned regularly to maintain continuous extraction. The cleaning interval
depends on the welding process. We recommend that the filter members are cleaned at least every 2 hours,
however no later than when the service LED illuminates. The service life of the filter membranes can be
lengthened if they are cleaned before the service LED illuminates.
NOTICE
Shorter service life due to lack of cleaning
If the welding process is interrupted, automatic cleaning of the filter membranes is run after a run-on time
of 20 seconds. If the welding process is started before the 20 seconds expire, cleaning does not occur.
The service life of the filter membranes is shortened.
► Ensure that the welding process is interrupted at least every 2 hours for a minimum of 20 seconds, or
set the <On/Off> switch to <Off> to run cleaning.
Set the <Auto/Manual> switch to <Auto> to
1
activate the automatic starting function.
Set the <On/Off> switch to <On>.
2
The filter membranes are cleaned once.
Once the welding process begins, the device
receives a signal from the current clamp and
automatically starts the fume extraction process. If
the welding process is interrupted, extraction
stops after 20 seconds, after which the cleaning
process is automatically run.