Index Subindex
Name
262
1
Power Supply Vol-
tage Lifetime Histo-
gram.Mode
262
2
Power Supply Vol-
tage Lifetime Histo-
gram Unit
262
3
Power Supply Vol-
tage Lifetime Histo-
gram RangeStart
262
4
Power Supply Vol-
tage Lifetime Histo-
gram RangeEnd
262
5
Power Supply Vol-
tage Lifetime Histo-
gram Nbr of Bins
262
11 ... 26
Power Supply Vol-
tage Lifetime Histo-
gram Bin1...16
Device Temperature
265
1
Temperature Life-
time Histo-
gram.Mode
265
2
Temperature Life-
time Histogram Unit
265
3
Temperature Life-
time Histogram Ran-
geStart
265
4
Temperature Life-
time Histogram Ran-
geEnd
Value
Data type Access rights
range
Uint8
R
Uint16
R
Uint32
R
Uint32
R
Uint8
R
Uint32
R
Uint8
R
Uint16
R
Uint32
R
Uint32
R
Description
Standard means: Linear partition of the range into bins.
Indicates the unit
Defines, where the range starts.
Defines, where the range ends.
Number of bins
Number of counts of each bin
Standard means: Linear partition of the range into bins.
Indicates the unit
Defines, where the range starts.
Defines, where the range ends.

Publicité