5.1.3.7
SSC4 Configuration
Index Subindex
Setpoints
16386 1
16386 2
Config
16387 1
16387 2
85
31
85
32
Time Filter
121
32
120
32
122
32
Name
Data type Access rights
Setpoints.SSC4 Pa-
Uint32
ram SP1
Setpoints.SSC4 Pa-
Uint32
ram SP2
SSC4 Config.Logic
Uint8
SSC4 Config.Mode
Uint8
SSC4 Selection
Uint8
SSC4 Auto Reset
Uint16
Response De-
Uint32
lay.SSC4 Time
Release De-
Uint32
lay.SSC4 Time
Minimum Pulse Du-
Uint32
ration.SSC4 Time
Value
range
Description
R/W
R/W
R/W
Selects the SSC logic:
Normal
n
Inverted
n
R/W
Selects the SSC switch mode.
Single Point
n
Window
n
R/W
Selects the switch counter that is used as input of SSC4:
SSC1 Switch Counter
n
SSC2 Switch Counter
n
R/W
Auto Reset of switch counter if value of SSC4 Param.SP1
(Single point) or Param.SP2 (Window) is reached.
Disabled
n
Enabled
n
R/W
Sets the response delay time
0 to 60.000 ms
R/W
Sets the release delay time
0 to 60.000 ms
R/W
Sets the minimum pulse duration
0 to 60.000 ms