Télécharger Imprimer la page

Baumer IF250 Mode D'emploi page 40

Publicité

Les langues disponibles

Les langues disponibles

5.1.3.2
Measurement Values
Index Subindex
1000 –
225
2
225
12
225
22
225
32
88
1
88
3
88
4
88
5
5.1.3.3
MDC Configuration
Index Subindex
83
1
16512 1
16512 2
Name
Data type Access rights
Baumer Command
Int32
(SSCx Switch
Counts Reset)
SSC1 Switch Counts
Int32
Resetable
SSC2 Switch Counts
Int32
Resetable
SSC3 Switch Counts
Int32
Resetable
SSC4 Switch Counts
Int32
Resetable
Measurement Va-
Int16
lue.Distance
Measurement Va-
Int32
lue.Frequency
Measurement Va-
Int16
lue.Amplitude
Measurement Va-
Int16
lue.Amplitude Offset
Name
Data type Access rights
Source
Uint8
Lower Limit
Uint32
Upper Limit
Uint32
Value
range
Description
W
Command to set the counter value of SSCx to zero. Avai-
lable for SSC1, 2, 3 and 4.
R
SSC1 Resetable Switch Counts
R
SSC2 Resetable Switch Counts
R
SSC3 Resetable Switch Counts
R
SSC4 Resetable Switch Counts
R
Distance measuring value
R
Frequency measuring value which is created by analyzing
the distance.
Measurement is independent of SSC settings.
R
For diagnostics or for evaluating the application/set up for
frequency measurements.
R
For diagnostics or for evaluating the application/set up for
frequency measurements.
Value
range
Description
R/W
Defines the measuring value which is mapped to the MDC
channel for availability via the process data IN path.
R
Lower limit of the measuring range.
R
Upper limit of the measuring range.

Publicité