Failure
Correction
Appliance cannot be
Turn the program selection switch to the desired programme.
started
Operate the safety switch.
Insert battery plug.
Check battery; charge it if required.
Make sure that all battery terminals are connected.
Insufficient water quan-
Check fresh water level, refill tank if necessary.
tity
Increase the water volume on the regulating knob for water volume.
Clean sieve.
Insufficient vacuum per-
Clean the seals between waste water tank and cover and check for tightness, replace if required.
formance
Wastewater reservoir is full; shut off the appliance and empty the wastewater reservoir
Clean the fluff filter.
Clean the vacuum lips on the vacuum bar, replace if required
Check if the cover on the dirt water discharge hose is closed
Check the setting of the vacuum bar.
Check suction hose for blockages; clean if required.
Check the suction hose for tightness; replace if required.
Insufficient cleaning re-
Check the brushes for wear, replace if required.
sult
Increase the water volume.
Check the brush type and the detergent for their suitability.
Suction turbine is run-
Clean the swimmer.
ning rough
Brush does not turn
Check if foreign objects block the brush; remove foreign object if required.
If over-current switch in the electronics system has been triggered, turn programme selection switch to "OFF".
Afterwards, set it back to the desired programme.
Vibrations during clean-
You might need to use a softer brush.
ing
In case of faults that cannot be remedied using the table below please contact the customer service.
Cleaning the floater
 Open the cover of the waste water tank.
1 Swimmer casing
2 Lock hook
3 Float
4 Lower part
 Pull out the float casing towards the top.
 Detach locking hooks.
 Clean float and bottom part.
 Assemble the float casing and insert it
into the device.