6. Commissioning, operation
GB
6.3 Mounting
Before mounting
Before starting the work, make sure that the conditions for mounting
the thermometer are met:
The plant is disconnected and free from pressure.
The plant has cooled down to ambient temperature.
There is a threaded fitting at a suitable position in the plant.
A suitable sealing material is used.
12
WARNING!
Only use suitable sealing material!
Hot media might escape if unsuitable sealing material
is used.
Unsuitable sealing material may cause damage to the
plant and pollution of the environment.
Use a sealing material that is suitable for the tempera-
ture range, and that is resistant to the medium being
measured.
WIKA operating instructions model 32