5.5.3 Filling with electric pump
Attention!
Hazard from electric shock!
Ensure that the electrical cables /
connections are dry and clean.
i
Important!
The electric pump has a thermal overload
protection and a feature to avoid risks
caused by overload. The intervention of this feature
causes the pump to switch off automatically, but
does not deactivate the main switch. It is important
to switch the pump off using its switch. Once
normal operating conditions have been restored,
the pump can be switched back on. Should the
protective shut­off trip during normal operating
conditions, please contact the Technical Service.
1. Open seal and door of the pump cabinet a.
2. Connect the connection cable/plug of the electric
pump to a suitable power source, see type plate
on tank or pump.
Important!
Risk of explosion.
3. Open the delivery line ball valve g.
4. Switch the electric pump k on at switch l.
5. Remove the hose n and automatic delivery
nozzle m from the pump cabinet and insert
the delivery spout fully into the container/tank
to be filled.
6. Operate the automatic delivery nozzle
(if necessary, lock with locking device)
and carry out filling operation.
b
a
7. Close automatic delivery nozzle m and allow to
stop dripping.
8. Switch electric pump k off at switch l.
9. Completely disconnect pump from power source,
roll up cable and place in pump cabinet.
All manuals and user guides at all-guides.com
Trigger for starting flow
a
b
Locking device
10. Roll up the hose and hang the delivery nozzle
in the holder in the pump cabinet.
11. Close the delivery line ball valve g.
12. Close seal and door of the pump cabinet.
GB
25

Publicité

loading

Ce manuel est également adapté pour:

Ks-mobil 600 lKs-mobil 980 l