Section 6
Problem
Unit running in AUTO but no
power in house.
Unit shuts down during
operation.
Unit was running and shut
down. Attempts to restart.
After activation, unit will not
start in AUTO with utility loss.
Unit will not start in AUTO with
utility loss.
Unit will not start in AUTO with
utility loss.
Unit will not start in AUTO with
utility loss.
Unit will not start in AUTO with
utility loss.
Unit will not start in AUTO with
utility loss.
Unit will not start in AUTO with
utility loss.
Control panel indicates
battery problem.
Control panel indicates
charging problem.
Control panel indicates
break-in maintenance due.
Control panel indicates
maintenance due.
Utility present. Active mode
LED (AUTO/MANUAL/OFF) is
flashing.
Automatic Standby Generator Owner's Manual
Quick Reference Guide
Things to Check
Check MLCB
Check for alarms
Check for alarms
See if unit is activated
Check for alarms
Check for alarms
Check for alarms
Check for alarms
Check for alarms
Check for alarms
Check for additional
information
Check for additional
information
Check for additional
information
Check for additional
information
Check utility sense lines/
utility disconnect
Active Alarm
Check MLCB. Contact servicing dealer if
NONE
MLCB is in the ON position.
Check ventilation around the generator,
HIGH
intake, exhaust and rear of generator. If
TEMPERATURE
no obstruction contact servicing dealer.
Clear alarm and remove household loads
from the generator. Put back in AUTO
RPM SENSE LOSS
and restart. If problem returns, contact
servicing dealer to investigate possible
fuel issue.
Refer to activation section in Owner's
NOT ACTIVATED
Manual.
Check oil level. Add oil per Owner's
LOW OIL LEVEL
Manual. Contact servicing dealer if oil
level is correct.
Clear alarm. Contact servicing dealer if
RPM SENSE LOSS
battery is GOOD. Replace battery if
battery problem is displayed.
Check fuel line shutoff valve is in the ON
position. Clear alarm. Attempt to start the
OVERCRANK
unit in MANUAL. If it does not start or
starts and runs rough, contact servicing
dealer.
Check ATO 7.5 Amp ATO
NO LEDs LIT
with same type fuse if bad.
Contact servicing dealer if fuse is good.
OVERSPEED
Contact servicing dealer.
UNDERSPEED
WIRING ERROR
Contact servicing dealer.
BATTERY PROBLEM
Contact servicing dealer.
CHARGER PROBLEM
Contact servicing dealer
Break in
Perform break in maintenance. Clear
Maintenance Due
maintenance due light.
1 Year / 100 Hour
Perform scheduled maintenance. Clear
Maintenance Due
maintenance due light.
Contact servicing dealer. Close utility
NONE
disconnect.
Solution
®
fuse. Replace
29