NOTE: The wheels are not intended for over-
the-road use.
Install wheels as follows. See
1. Slide axle pin (B) through the wheel (A),
wheel bracket on frame, and flat washer
(L).
2. Insert cotter pin (F). Bend tabs (of cotter
pins) outward to lock into place.
Install frame foot as shown in
1. Place frame foot assembly (C) under
frame. Secure with M8-1.25 x 45 bolts (J)
and M8-1.25 hex flange nut (G).
.
B
A
L
Figure 2-15. Wheel & Frame Foot Assembly
Install handle as shown in
1. Install handle bracket (E) to frame with
M8-1.25 x 40 bolts (H).
2. Slide M8-1.25 x 55 bolts (K) through han-
dle bracket and handle (D). Install M8-1.25
hex flange nut (G).
.
Figure 2-16. Handle Assembly
Add Engine Oil
Engine damage. Verify proper type and quantity of
engine oil prior to starting engine. Failure to do so
could result in engine damage.
1. Place generator on a level surface.
2. Clean area around oil fill.
3. Remove oil fill cap and wipe dipstick clean.
See
Figure
2-17.
10
Figure
2-15.
Figure
2-15.
J
F
G
C
Figure
2-16.
E
H
G
CAUTION
(000135)
4. Add recommended engine oil. Climate
determines proper engine oil viscosity.
See chart to select correct viscosity.
NOTE: Use petroleum based oil (supplied) for
engine break-in before using synthetic oil.
.
000902
NOTE: Some units have more than one oil fill
location. It is only necessary to use one oil fill
point.
5. Thread dipstick into oil filler neck. Oil level
is checked with dipstick fully installed.
K
6. See
ify oil level is within safe operating range.
D
000903
Figure 2-18. Safe Operating Range
7. Install oil fill cap/dipstick and hand-tighten.
Figure 2-17. Remove Dipstick
10W-30
Synthetic 5W-30
Figure
2-18. Remove dipstick and ver-
Owner's Manual for Portable Generator
000115
SAE 30
000399
000116