5.2 Sensor setup menu (continued)
40 %, 30 %, 15 %
Module status: Error
14 %,10 %,8 %, OFF
Sample detection
Off/Warning/Error
Drain blockage
On/Off
Electrolyte warning
Warning/Off
Incorrect electrode data
Error/Off
Reset
Last change
Maintenance
Information
Location 1
Location 2
Type
Sensor type
Serial number
Range
Option
Software filtration probe
Software AMTAX
Bootloader
Application
Structure
Firmware
Content
Language
Calibration history
Location 1
Gain correction
Date
Location 2
Gain correction
Date
Maintenance (continued)
English
All manuals and user guides at all-guides.com
Warning is released: when a filter probe is installed and the status of filtration modules fall
below level
An error is generated: when a filter probe is installed and the status of filtration modules fall
below level. When switched to OFF, a deactivated sample detection will be switched to
"warning".
Determines instruments reaction when amount of available sample is too low. When
instrument is in filter probe mode, deactivating the sample detection will switch a deactivated
"Module status: Error" to 14 %
Determines instrument reaction when drain is blocked
Determines whether a warning is initiated when electrolyte level is low/ last change of
membrane is more than 90 days ago.
Determines whether an error is initiated when the mV-Zero value of the electrode is not
within a certain range (see list of errors)
Resets factor and settings to factory settings.
Indication of the last change of a setting in the configuration menu.
Indication of measuring location 1
Indication of measuring location 2 on two-channel version
Indication of instrument type
Indication of instrument name
Indication of serial number
Indication of measuring range
Indication of instrument option (filtration probe/1-channel/2-channel)
Filtration probe software
Instrument software
Detailed information on the software in the instrument
Detailed information on the software in the instrument
Detailed information on the software in the instrument
Detailed information on the software in the instrument
Detailed information on the software in the instrument
List of languages that are supported by the installed language package.
Indication of measuring location 1
Indicates the correction factor set for correcting the measured values at measuring location
1.
Indicates the date of the last change to the correction factor.
Available with the 2-channel version.
Indicates the correction factor set for correcting the measured values at measuring location
2.
Indicates the date of the last change to the correction factor.
Operation
7