Product description

4.1

Construction

2
6
5
Fig. 1: Structure
4.1.1

Technical data

4.1.2

Dimensions

Fig. 2: Dimension drawings
4.1.3
Materials
4.2

Mode of operation

Installation and operating instructions Wilo-DrainLift WS 40/50 Basic
Product description
1
Chamber cover
1
2
Pressure pipe connection
2
3
Pump chamber
4
Drain pipe/diaphragm hand pump connection
3
5
Venting line connection
6
Cable pipe connection
4
Chamber
Pump chamber with optimised geometry for deposit-free operation. Chamber compo-
nent with ribbing for high inherent stability and buoyancy safety. The inlets are freely
configurable. Two lifting eyes are integrated for attaching the lifting equipment. The
chamber cover can be walked on and can be loaded with max. 200 kg. For the building
installation, the pump chamber is equipped with a floor fixation.
Pipework
ƒ
Discharge pipe with threaded connection on the pump side
ƒ
Shut-off ball valve
ƒ
Non-return ball valve
Level control
Depending on the type, the level is controlled via the float switch of the pump, a separ-
ate float switch or a level sensor. If the level is controlled with a separate float switch or
level sensor, it is controlled via switchgear.
ƒ
Vessel volume: 255 l/67 US.liq.gal. (WS...E)/400 l/105 US.liq.gal. (WS...D)
ƒ
Maximum pressure in the pressure pipe: 1.5 bar (22 psi)
ƒ
Pressure connection: G 2/50 mm (WS 40), G 2½ /63 mm (WS 50)
ƒ
Inlet connection: DN 100/150/200
ƒ
Aeration and ventilation connection: 75 mm (3 in)
ƒ
Cable pipe for ground installation: 63 mm (2.5 in)
ƒ
Threaded cable glands for building installation:
- WS...E: 1x M25 + 2x M16
- WS...D: 2x M16 + 2x M25
ƒ
Fluid temperature: 3 ... 40 °C (37 ... 104 °F)
ƒ
Max. ambient temperature: 3 ... 40 °C (37 ... 104 °F)
ƒ
Max. ground water level: 500 mm
Refer to the dimension drawing for the dimensions:
1
DrainLift WS 40E
2
DrainLift WS 40D
3
DrainLift WS 50E
4
DrainLift WS 50D
When the pump chamber extension is installed, the dimensions change as follows:
Pump chamber extension height
Pump chamber total height
Max. vessel volume
Max. ground water level
ƒ
Pump chamber: PE
ƒ
Pipework: 1.4404 (AISI 316L)
ƒ
Stopcock: PVC
ƒ
Non-return valve: Grey cast iron
The sewage produced is channelled into the pump chamber via the inlet, where it col-
lects. When the water level reaches the switch-on level, the pump is switched on. The
collected sewage is pumped into the on-site pressure pipe via the discharge pipe. When
DrainLift WS ... E
DrainLift WS ... D
300 mm (12 in)
300 mm (12 in)
1342 mm (53 in)
1342 mm (53 in)
325 l (86 US.liq.gal)
470 l (124 US.liq.gal)
1000 mm (39 in)
500 mm (19.5 in)