INSTALLATION INSTRUCTIONS
GAS HOOK-UP
Only the pressure regulator and hose assembly supplied with the grill should be used. Any replacement
pressure regulator and hose assembly must be specified by the grill manufacturer. This grill is configured for
Liquid Propane. Do not use a Natural Gas supply.
Total gas consumption (per hour) with all burners set on "HI":
Main burners
Total
The installation of this appliance must conform with local codes or, in the absence of local codes, with
either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, National Gas Propane Installation Code, CSA
B149.1, or Propane Storage and Handling Code, B149.2,or the Standard for Recreation Vehicles, ANSI
A119.2/NFPA 1192, and CSA Z240 RV Series, Recreation Vehicle Code, as applicable.
LIQUID PROPANE CYLINDER REQUIREMENTS
(20-lb./9kg Cylinder)
A dented or rusty Liquid Propane cylinder may be hazardous and should be checked by your supplier. Never
use a cylinder with a damaged valve. The Liquid Propane cylinder must be constructed and marked in
accordance with the specifications for Liquid Propane cylinders by the United States Department of
Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes
for Transportation of Dangerous Goods Commission.
The 20-lb./9kg cylinder must have a shut-off valve terminating in a valve outlet specified, as applicable, for
connection type QCC1 in the standard for compressed gas cylinder valve outlet and inlet connection
ANSI/CGA-V-1.
Storage of an outdoor cooking gas appliance indoor is permissible only if the cylinder is disconnected and
removed from the outdoor cooking gas appliance. The cylinder system must be arranged for vapour
withdrawal. The cylinder must include a collar to protect the cylinder valve.
Manifold pressure: (operating) 11 inches (27.9cm) water column (W.C.), (non-operating) 11.2 inches (28.4cm)
water column (W.C.).
The Liquid Propane cylinder must be fitted with an Overfill Protection Device (OPD).
Remove the plastic valve cover from the Liquid Propane cylinder. Make sure the grill gas hoses do not contact
the grease pan or grill firebox when the Liquid Propane cylinder is placed into the cart.
CONNECTING THE LIQUID PROPANE CYLINDER
To connect the Liquid Propane gas supply cylinder:
The cylinder valve should be in the "OFF" position. If not, turn the valve clockwise until it stops.
Make sure the cylinder valve has the proper type-1 external male thread connections per ANSI Z21.81.
Make sure the burner valves are in the "OFF" position.
Inspect the valve connections, port and regulator assembly. Remove debris and inspect the hose for damage.
When connecting the regulator assembly to the valve, use your hand to tighten the nut clockwise until it stops.
Use of a wrench could damage the quick coupling nut and result in a hazardous situation
Open the cylinder valve fully by turning the valve counterclockwise.
Before lighting the grill, use a soap and water solution to check all the connections for leaks.
If a leak is found, turn the cylinder valve "OFF" and do not use the grill until a local Liquid Propane dealer can
make repairs.
WARNING
Never attempt to use damaged or obstructed equipment. See your local Liquid Propane dealer for repair.