Toshiba RAV-SM562BT-E Manuel D'installation page 30

Masquer les pouces Voir aussi pour RAV-SM562BT-E:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
10
APPLICABLE CONTROLS
Procedure
If there is other indoor unit to be changed, repeat
2
procedure
to
When the above setup has finished, push
select the indoor unit No. before change of setup, specify
CODE No. [12], [13], [14] in order with temp. setup
/
buttons, and then check the changed contents.
6
Address change check Before change:
[3-3-1] → After change: [2-2-2]
CL
Pushing
button clears the contents of which setup was changed.
(In this case, procedure from
After check of the changed contents, push
display disappears and the status becomes the usual stop status. (When pushing
the remote controller is not accepted for approx. 1 minute.)
* If the operation from the remote controller is not accepted even
7
1 minute or more passed after pushing
considered that the address setup is incorrect.
In this case, the automatic address must be again set up.
Therefore repeat procedure of the setup change from the Procedure
To recognize the position of the corresponding
indoor unit though the indoor unit No. is known
Check the position during operation stop.
(Be sure to stop operation of the set.)
Procedure
Push simultaneously
After a while, the display part flashes and the display appears as shown below.
In this time, the position can be checked because fan of the indoor unit operate.
• For the group control, the indoor unit No. is displayed as [
fans of all the indoor units in the group control operate.
1
Check the displayed CODE No. is [01].
• When the CODE No. is other than [01], push
erase the display and repeat procedure from the first step.
(After pushing
is not accepted for approx. 1 minute.)
In the group control, every pushing
2
In this time, the position of the indoor unit can be confirmed because only fan of the selected indoor unit
operate. (For a group control, No. of the firstly displayed indoor unit becomes the header unit.)
After confirmation, push
usual mode.
When pushing
3
becomes the usual stop status.
(When pushing
is not accepted for approx. 1 minute.)
All manuals and user guides at all-guides.com
5
to change the setup.
UNIT
LOUVER
2
is repeated.)
TEST
TEST
button, it is
VENT
TEST
+
buttons for 4 seconds or more.
TEST
button, operation of the remote controller
UNIT
LOUVER
button, the indoor unit No. in the group control is displayed in order.
TEST
button to return the mode to the
TEST
button, the display disappears and the status
TEST
button the operation from the remote controller
Description
Indoor unit No. before setup change is displayed.
to
button. (Setup is determined.) When pushing
1
.
1, 3
Description
] and
TEST
button to
(
to the model No. of indoor unit.)
27
TEST
button, the
TEST
button the operation from
TEMP.
ON / OFF
TIMER SET
FAN
MODE
TIME
SAVE
VENT
FILTER
RESET
TEST
SET
CL
SWING/FIX
UNIT LOUVER
Display changes according
1
2