Keypad
Problem
Green start LED
flashes.
Red error LED flash-
es.
The product does not
start.
Red error LED
comes on.
Battery
Problem
Green LED flashes.
Red error LED flashes.
Red error LED comes on.
Battery charger
Problem
Red error LED flashes.
Red error LED comes on.
16
Troubleshooting
Possible faults
Low battery voltage.
Overload.
Temperature deviation.
The power trigger and the start button are
pushed at the same time.
Dirt in the battery connectors.
It is necessary to do servicing on the product. Speak to your servicing dealer.
Possible faults
Low battery voltage.
The battery is empty.
Temperature deviation.
Overvoltage.
Cell difference is to much (1V).
Possible faults
Temperature deviation.
Possible solution
Charge the battery.
The cutting attachment is blocked. stop the
product. Remove the battery. Clean the cut-
ting attachment from unwanted materials.
Loosen the chain.
Let the product become cool.
Release the power trigger and push the start
button.
Clean the battery connectors with com-
pressed air or a soft brush.
Possible solution
Charge the battery.
Charge the battery.
Use the battery in temperatures between
-10°C (14°F) and 40°C (104°F).
Remove the battery from the battery charger.
Speak to your servicing dealer.
Possible solution
Use the battery charger in tempera-
tures between 5 °C (41 °F) and 40 °C
(104 °F).
Speak to your servicing dealer.