Troubleshooting (cont.)
Symptoms
17. Water splashes off the
drip tray onto the floor.
Kohler Co.
All manuals and user guides at all-guides.com
Probable Causes
C. The door power wiring
connection to the controller is
loose.
D. The drain valve is connected to
another 120 V outlet or is not
plugged into the controller.
E. One or both of the limit
switches are not making contact
or are damaged.
F.
The level sensor circuit is not
detecting water within 2
minutes of raising the door.
G. The drain valve is not working.
H. The wire connections are loose.
I.
The internal wire connections
inside the door are loose.
J.
The primary seal system is not
operating properly or the air
line may be pinched.
K. The secondary seal systems are
not operating properly or the air
line may be pinched.
L. There is an air leak inside the
door.
M. The compressor is not working.
N. The pressure switch inside the
door is not working or is
leaking air.
O. The controller is not working.
A. The brush seal is not installed
or is not adjusted correctly.
47
Recommended Action
C. Connect the door power wire to the
J6 port in the controller.
D. Plug the drain valve directly into J2
in the controller.
E1. Adjust the limit switch/switches
until contact is made.
E2. The limit switch/switches need to
be replaced. Call the Customer
Care Center using the information
provided on the back page of this
manual.
F.
Check the level probes and wires
for proper connection to the
controller.
G. Replace the drain valve or call the
Customer Care Center using the
information provided on the back
page of this manual.
H1. Check the power cord from the
outlet to the controller.
H2. Check the drain valve power cord
to the controller.
H3. Check the level probe wiring to the
controller.
H4. Check the limit switch wiring to
the controller.
H5. Check the door power cord to the
controller.
I.
Call the Customer Care Center
using the information provided on
the back page of this manual.
J.
Call the Customer Care Center
using the information provided on
the back page of this manual.
K. Call the Customer Care Center
using the information provided on
the back page of this manual.
L. Call the Customer Care Center
using the information provided on
the back page of this manual.
M. The compressor needs to be
replaced. Call the Customer Care
Center using the information
provided on the back page of this
manual.
N. Call the Customer Care Center
using the information provided on
the back page of this manual.
O. The controller needs to be replaced.
Call the Customer Care Center
using the information provided on
the back page of this manual.
A. Install or adjust the brush seal.
1128532-2-G