Troubleshooting (cont.)
Symptoms
15. The bath will fill to the
overflow, but fails to
maintain its water level.
16. The seal will not inflate.
1128532-2-G
All manuals and user guides at all-guides.com
Probable Causes
B. Accumulator attachment is
damaged or leaks.
C. Water is splashing over the top
of the seal.
D. The door gap is too big because
the pulley assembly is not
properly adjusted.
A. Toe tap drain is open, does not
close, or is leaking.
B. There is no power to the
controller.
C. One or both of the limit
switches are not making contact
or are damaged.
D. Water is splashing over the top
of the seal.
E. There is debris between the
door and seal.
F.
The drain valve is not working.
G. The controller is not working.
A. There is no power to the
controller or bath.
B. Error code in controller has
been activated (beeping sound
heard).
46
Recommended Action
B. Reconnect or tighten the
accumulator drain line connection.
C. Lower the water level when filling
the bath. Reduce sudden
movements while bathing.
D. Adjust the pulley assembly inward.
A. Close and/or clean the toe tap
assembly. Reseal and reattach the
drain. Replace if needed.
B. Plug in both ends of the controller
power cord or reset the breaker.
C1. Adjust the limit switch/switches
until contact is made.
C2. The limit switch/switches need to
be replaced. Call the Customer
Care Center using the information
provided on the back page of this
manual.
D. Lower the water level when filling
the bath. Reduce sudden
movements when bathing.
E. Clean all debris off the seal using a
can of compressed air.
F.
The drain valve needs to be
replaced. Replace the drain valve or
call the Customer Care Center
using the information provided on
the back page of this manual.
G. Replace the controller or call the
Customer Care Center using the
information provided on the back
page of this manual.
A1. Connect the controller to the power
supply.
A2. Reset the circuit breaker.
A3. Connect the bath power cord to the
J1 port on the controller.
B1. Reset the controller. To do this;
lower the door
quickly tap the door switch 5
times
wait 3 seconds, then tap the
switch 11 times within a 5
second span
the controller should beep 3 to
5 times to indicate the issue
has been resolved, then go
quiet.
B2. If the error code is still activated or
reoccurs, unplug the power and
call the Customer Care Center
using the information provided on
the back page of this manual.