the cargo area floor is a machinery
guard and its removal exposes the
operator to moving parts. Keep
hands, hair and clothing away from
belts and pulleys
MOTOR BRUSH REPLACEMENT
At regular maintenance intervals, each motor brush
should be checked to determine if excessive wear
or damage is evident. If a brush is broken,
cracked, chipped or worn to a length of less than 5/
8" (15.9 mm), measured on the short side of the
brush, all brushes should be replaced. Never
replace a single brush.
see your authorized cushman dealer for service
required.
Motor terminals
Motor wire to motor terminal connections should be
clean and tight for maximum motor efficiency. Use
metal parts protector spray (part no. 841192).
LED DIAGNOSTICS
2
1
0
3
4
OFF
MAIN
CURRENT LIMIT
During normal operation, with no faults present, the Status LED flashes a single
flash at approximately 1 flash/second. If the controller detects a fault, a 2±digit
code (see Table) is flashed continuously until the fault is corrected. For exam-
ple, code ª3,2º ±welded direction contactor ± appears as:
GB-12
All manuals and user guides at all-guides.com
SAFETY, OPERATORS & MAINTENANCE MANUAL
2
2
1
1
0
0
3
3
4
4
OFF
OFF
PLUG
ACCEL.
(3,2)
PROGRAMMER ACCESSORY
A Controller Programmer is available, Part No. 893052
E-Z-GO XI 340 / CUSHMAN TUG
motor terminals should not be turned from
original position."hold terminal stud nut while
torquing the wire terminal retaining nuts 50 to
70 in.-lbs. (5.5 to 8 n·m).
Speed controller
The vehicle is equipped with an electronic speed
controller that does not require servicing.
Controller led status indicator
2
2
1
1
0
0
3
3
4
4
OFF
OFF
CREEP
LOW
SPEED LIMIT
(3,2)
(3,2)
NOTICE
5203