2-3 Parameters used for the data format
The following three kinds of parameters are prepared for the control command and response data.
(1) Numeric value
Designates the 2-byte hexadecimal value with the sign as the 4-digit (byte) characters.
Designation allowable range: "8000" to "7FFF"
(2) ON/OFF
Designates the status (ON/OFF) of the projector, such as POWER and HIDE.
Character
Hex.
"0"
30
"1"
31
(3) Special parameters
Input switching parameters:
Character
Hex.
"0"
30
"1"
31
"2"
32
"3"
33
"4"
34
"5"
35
Operation mode parameters:
Character
Hex.
"0000"
30h, 30h, 30h, 30h
"0001"
30h, 30h, 30h, 31h
"0002"
30h, 30h, 30h, 32h
"0004"
30h, 30h, 30h, 34h
3. Control command table
The control commands that can be sent from the computer are as follows:
Function
Command
OPERATE
U0F
HIDE
U00
Right Left rev.
U17
Top Bottom inv.
U18
Keystone
U40
Input
U1A
Operation mode
Z03
* Keystone: Numeric value can range from "FF80" to "0080"
* Operation mode: Only Asking command is possible
All manuals and user guides at all-guides.com
Meaning
OFF
ON
Meaning
Y/C
VIDEO
COMP
PC1
PC2
DVI
Meaning
Stand-by mode
Power-on mode
Cool-down mode
Warning mode
Asking
Power ON
ELSE
Numeric Value







RS-232C external control
Kind of data
ON/OFF





Y/C, VIDEO, PC1, PC2,
COMP, DVI
Stand-by, Power-on,
Cool-down, Warning
Special Data