8.1
E-9
System-specific parameters
To carry out a thermal disinfection, the DHW is heated up once to
the desired temperature. The heating period is terminated
automatically when the set temperature is reached or after 4 hours
at the latest.
Sets the start time for the thermal disinfection
Sets the desired hot water temperature which is to be reached
during thermal disinfection
For each day of the week, it is possible to select whether thermal
disinfection is desired at the set start time.
By setting Reset to "Yes", the maximum calculated hot water
temperatures in HP operation are reset to a value of 65 °C. The
setting is automatically reset to "No".
Sets the preparation of swimming pool water
Sets the time programs for swimming pool blocks
Sets the times in which swimming pool water preparation is
blocked
For each day of the week, it is possible to select whether Time1,
Time2, no time or both times are to be active when the
temperature is lowered. Operations to lower the temperature that
exceed a week day are activated or deactivated at the end of each
day accordingly.
Sets the date, year, day, month and week day
The language for menu navigation can be selected from the
available languages
Setting range
00:00
...
23:59
60 °C
... 45 °C ...
85 °C
N
Y
No
Yes
00:00
...
23:59
N
T1
T2
Y
DEUTSCH
ENGLISH
FRANCAIS
ITALIANO
NEDERLAND
CESKY