Troubleshooting (cont.)
Symptoms
7. Unit does not stop
automatically after 22 minutes.
8. Noisy operation.
9. Remote does not work.
1032118-2-A
Probable Causes
B. Motor overheated and
protection device activated.
A. Timer mechanism accidentally
deactivated.
A. Not enough water in footbath
basin.
B. Band straps (if applicable) on
the pump are not cut.
A. Remote not programmed.
26
Recommended Action
B. Check for restricted air space
around pump box, motor vent
blockage, suction/harness
blockage. Correct and allow
motor to cool.
A. See service manual. Refer to
installer/dealer.
A. Fill basin 3" (7.6cm) over top of
suction cover.
B. Cut band straps.
A. Re-program remote following
instructions.