Troubleshooting; Troubleshooting Guide - Kohler K-1000-H2 Instructions D'installation

Masquer les pouces Voir aussi pour K-1000-H2:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

32. Troubleshooting

Troubleshooting Guide

This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified
electrician should correct any electrical problems. For warranty service, contact your dealer or wholesale
distributor.
Symptoms
1. Unit does not start or stop.
2.
Water flow surges.
3.
Motor starts, all bodyjets are
not functioning.
4.
Motor starts, waterfall does not
function.
5.
Waterfall lights do not work.
6. Unit stops automatically before
18 minutes.
Kohler Co.
Probable Causes
A. No power to
pump/receptacle/keypad.
B. Harness is blocked.
C. Keypad disconnected from
pump/control box.
D. Keypad doesn't work.
E. Not enough water in footbath
basin.
F.
Motor/pump assembly does
not work.
G. Control does not work.
A. Not enough water in footbath
basin.
B. Suction is blocked.
C. Harness is blocked.
A. Bodyjet is blocked.
B. Bodyjet butterfly valve wiring
loose or damaged, or butterfly
valve is faulty.
C. Not enough water in footbath
basin (pump cavitates).
D. Keypad does not work.
E. Control does not work.
A. Waterfall is blocked.
B. Waterfall wiring
loose/damaged or butterfly
valve is faulty.
C. Not enough water in footbath
basin (pump cavitates).
D. Keypad does not work.
E. Control does not work.
A. Loose or damaged wiring.
B. Power supply for lighting does
not work.
A. GFCI or ELCB has tripped.
25
Recommended Action
A. Set/Reset GFCI or ELCB.
Check wiring. Refer to
installer/dealer.
B. Remove blockage.
C. Reconnect keypad and/or
wiring harness.
D. Replace keypad. Refer to
installer/dealer.
E. Fill basin 3" (7.6cm) over top of
suction cover.
F.
Replace motor/pump
assembly. Refer to
installer/dealer.
G. Replace control. Refer to
installer/dealer.
A. Fill basin 3" (7.6cm) over top of
suction cover.
B. Remove obstruction.
C. Remove blockage.
A. Remove blockage.
B. Identify source of fault and
correct or replace wiring or
butterfly valve. Check all
wiring. Refer to
installer/dealer.
C. Fill basin 3" (7.6cm) over top of
suction cover.
D. Replace keypad. Refer to
installer/dealer.
E. Replace control. Refer to
installer/dealer.
A. Remove blockage.
B. Identify source of fault and
correct or replace wiring or
butterfly valve. Refer to
installer/dealer.
C. Fill basin 3" (7.6cm) over top of
suction cover.
D. Replace keypad. Refer to
installer/dealer.
E. Replace control. Refer to
installer/dealer.
A. Identify source and correct.
Refer to installer/dealer.
B. Replace lighting supply box in
tower. Refer to installer/dealer.
A. Set/Reset GFCI or ELCB.
1032118-2-A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

K-1015K-1016K-5161

Table des Matières