Connect The Electrical Service - Standard - Kohler K-1110 Mode D'emploi

Masquer les pouces Voir aussi pour K-1110:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The junction box should be
wired as shown.
Brown
Electrician to
provide suitable
strain relief.
Supply
Blue

6. Connect the Electrical Service - Standard

WARNING: Risk of electric shock. To reduce the risk of electric shock, connect the control to a
properly grounded Ground-Fault Circuit-Interrupter (GFCI) or Earth-Leakage Circuit-Breaker (ELCB).
This will provide additional protection against line-to-ground shock hazard. A 220-240 V, 15 A, 50/60
Hz dedicated circuit is required.
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing the
following procedures.
NOTE: The bath model number is printed on a label near the bath blower motor. This label also identifies
the electrical rating of the bath. All baths come equipped with a wiring junction box and will only
operate at 220 V through 240 V and at 50 Hz or 60 Hz.
IMPORTANT! The bath controls, bath system, and wiring harness have been prewired at the factory. A
licensed electrician should make a routine service connection to the supplied junction box.
Connect the electrical service to the junction box.
Provide a separate equipment grounding or earthing conductor for the spare grounding/earthing
lug located on the junction box. This conductor must not be connected to any current-carrying
conductor. Follow local electrical codes.
Bond in accordance with national and local codes.
Clean the area of all dust and debris.
NOTE: Your wiring harness includes an antenna for the optional remote control. Do not alter or damage
this antenna during installation.
Ensure all wires on the wiring harness are securely fastened.
Kohler Co.
Bond in accordance with
national and local codes.
Ground (Green with Yellow Stripe)
Wire Connectors
From Control
60 Hz 50 Hz From Control
L1
L1
Brown
L2
N
Blue
11
Check
Valve
Control
External Power
Blower
Motor Cord
Control
Power Supply
1035472-2-E