Troubleshooting Procedures (cont.)
Symptoms
9. Blower motor won't turn off
when the power button on
user keypad is pressed.
10. A zone does not produce air
bubbles but another zone
operates normally.
11. Surge mode does not work.
12. Water spillage or damage
observed under the bath.
13. Bath does not purge
automatically.
For Baths with Chromatherapy
Symptoms
14. Chromatherapy lights do not
work.
15. Chromatherapy does not cycle.
Kohler Co.
Probable Causes
B. Loose, disconnected, or
damaged wiring harness.
C. User keypad does not work.
D. Blower motor does not work.
E. Control does not work.
A. User keypad does not work.
B. Loose, disconnected, or
damaged wiring harness.
C. Control does not work.
A. Zone is not selected.
B. Butterfly valve does not work.
C. Loose, disconnected, or
damaged wiring harness.
D. User keypad does not work.
E. Control does not work.
A. User keypad does not work.
B. Control does not work.
A. Drain or overflow leaking.
B. Wall, deck, and/or shower
door is improperly sealed.
C. Cracked acrylic air channels.
A. Level sensor wires are
disconnected.
Probable Causes
A. Loose, disconnected or
damaged wiring/connections.
B. Control does not work.
A. Chromatherapy harness
assemble does not work.
31
Recommended Action
B. Check wiring for proper
connections. Replace the wiring
harness if necessary.
C. Replace the user keypad.
D. Replace the blower motor.
E. Replace the control.
A. Replace the user keypad.
B. Check wiring for proper
connections. Replace the wiring
harness if necessary.
C. Replace the control.
A. Select the zone as per the
instructions in the "Confirm
Proper Operation" section.
B. Replace the butterfly valve.
C. Check wiring for proper
connections. Replace the wiring
harness if necessary.
D. Replace the user keypad.
E. Replace the control.
A. Replace the user keypad.
B. Replace the control.
A. Repair or replace the drain
assembly as per the
manufacturer's instructions.
B. Apply silicone sealant at the
seams between the bath and
the wall, deck, or door.
C. Refer to the manufacturer.
A. Connect the level sensor wires.
Recommended Action
A. Check wiring for proper
connections. Replace wiring if
necessary.
B. Replace control.
A. Replace the chromatherapy
harness assembly.