Make Electrical Connections - Standard - Kohler K-723 Guide D'installation

Baignoire à jets d'air
Masquer les pouces Voir aussi pour K-723:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Bond in accordance with national and
local codes. Open bonding lugs are
located at the top of the junction box.
120/240 VAC Source
N
L1
120 V
120 V
240 V
S/N
Neutral Bus
(In Breaker Box)

7. Make Electrical Connections - Standard

NOTE: The product model number is printed on a label on the blower side of the bath. This label also
identifies the electrical rating of the product. All baths come equipped with a wiring junction box and are
designed to operate between 220 VAC and 240 VAC at either 50 Hz or 60 Hz.
WARNING: Risk of electrical shock. Make sure the power has been disconnected before
performing the following procedures. Refer to the "Important Information" section.
WARNING: Risk of electrical shock. To reduce the risk of electrical shock, connect the blower to a
properly grounded Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). This
will provide additional protection against line-to-ground shock hazard. A 220-240 V, 15 A, 50/60 Hz
dedicated circuit is required.
NOTICE: The load neutral is not used. There should be no connection to the load neutral terminal on the
Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD). The green wire with the
yellow stripe is the equipment ground and needs to be connected to the neutral bus in the main circuit
breaker box.
NOTICE: The bath control and system have been pre-wired at the factory. A qualified electrician should
make a routine service connection to the junction box.
Connect service to the control power junction box. The junction box contains blue, brown, and green
with a yellow stripe colored wires. Follow local electrical codes. Bond in accordance with national
and local codes.
NOTE: A wiring harness has been pre-wired at the factory. No additional wiring is required, but ensure
that all wires are securely fastened.
NOTE: Your wiring harness includes an antenna for the optional remote control. Do not alter or damage
this antenna during installation.
1143444-2-A
All manuals and user guides at all-guides.com
L2
Breaker Box
Typical Two-Pole
Circuit Breaker
with GFCI
No Connection
(Load Neutral)
* Line Neutral
(White
Curly Wire)
* Equipment Ground
Check Valve
Control
Typical Wiring Connection for North America
* Connections to be Made
at the Circuit Breaker
*L2
Control Power
240 V
Junction Box
*L1
Blue (L1)
Field Wiring
(From Junction Box
to GFCI Breaker)
10
Blower Motor Cord
Control
Power Supply
External Power
Wire Connector
Ground
(Green with
Yellow Stripes)
From Control
Brown (L2)
Wire Connectors
Electrician to provide
suitable strain relief cable.