11.5.1 STATISTICS
STATISTICS Totals
The machine logs total number
of washes, total operated time
and total number of shot
medium collections.
STATISTICS Energy
The machine is equipped with
an advanced current monitoring
system which makes it possible
to determine the consumption
of the pump motor.
This is shown as an average
consumption/wash and is
automatically reset every time
the machine is cleaned. The
value is different depending
on how long the average wash
cycle is.
STATISTICS 7 days
The machine can also identify
the amount of use during the
last seven days, illustrated in
a graph. This can be used for
identifying peaks in work load.
11.5.2 Water Change
If the Clean Rinse option is
being used in the machine, the
water change intervals may be
increased to approximately 400
washes.
11.5.3 Work Hours/Intelligent
The GP 24 is equipped with
an intelligent water heating
system that saves up to 50%
more energy than a traditional
thermostat controlled heater.
Enter the time for when the
machine should be ready for
washing in the morning, the
time for when the machine is
no longer used in the afternoon
and which weekdays the
schedule should be active.
The machine will then
automatically start heating
the water in time so that it is
at desired temperature at the
"STARTTIME". The machine is
default set at 7:00-16:00, MON-
FRI. This means that the water
will be at operation temperature
between these hours.
If intelligent heating for some
reason isn't desired, set the time
schedule from 00:00-00:00,
MON-SUN and the heater will
keep the water warm 24 hours,
7 days a week.
230754-EN rev.1 2016-10-18
GP 24
Heater
11.5.4 Water temperature/Heater
The water temperature is
adjustable between 30-50°C.
The heater can also be turned
off by decreasing temp until
OFF is shown in LCD.
The factory setting of the water
temperature is 45ºC. This value
may NOT be increased since the
water will be too hot and lead to
risk of burning injuries
11.5.5 Time
It is important that time and
week day is correct since various
functions in the interface are
dependent on it..
11.5.6 Factory Reset
Use this to reset the machine
to factory standard. If you
accidentally entered the menu,
just press back or use the STOP-
button.
11.5.7 Version/Model
Shows what version of software
(SW) and hardware (HW) the
machine is using.
11.5.8 Self Test
The self test makes it possible to
run every function individually
in the machine. It is used i.e.
when new options are installed,
to control that they are working
properly. It can also be used for
troubleshooting the machine.
The self test should only be
used by authorized personnel.
11.5.9 Alarm Log
The alarm log saves all error
codes. The errors will be
displayed in the LCD when they
occur. These error codes are
saved to an alarm log where
you can go back and see type of
error code, how many days ago
it occurred and the time.
See chapter 19 Trouble
Shooting for error code list.
11.5.10 Language
Changes the language in settings.