Transporting/Tipping Of The Unit; Starting Pull Start Engines; Generator Shut Down - Generac GP Serie Manuel Du Propriétaire

Masquer les pouces Voir aussi pour GP Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Radio
*Refrigerator
Slow Cooker
*Submersible Pump (1-1/2 HP)
*Submersible Pump (1 HP)
*Submersible Pump (1/2 HP)
*Sump Pump
*Table Saw (10")
Television
Toaster
Weed Trimmer
* Allow 3 times the listed watts for starting these
devices.

Transporting/Tipping of the Unit

Do not operate, store or transport the unit at
an angle greater than 15 degrees.

Starting Pull Start Engines

Recoil Hazard. Recoil could retract unexpectedly.
Kickback could result in death or serious injury.
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. Unplug all electrical loads from the unit's
receptacles before starting engine.
2. Place generator on a level surface.
3. See
Figure
3-2. Open the fuel shut-off
valve (A).
4. Turn engine RUN/STOP switch (B) to
RUN. See
Figure
.
A
Figure 3-2.Engine Controls
5. Slide engine choke (C) to Full CHOKE
position (left). See
14
50 to 200
2800
2000
1500
800 to 1050
1750 to 2000
200 to 500
1000 to 1650
WARNING
CAUTION
3-2.
Figure
3-3.
700
200
500
6. See
(D) and pull slowly until increased resis-
tance is felt. Pull rapidly up and away.
7. When engine starts, move choke knob to
1/2 CHOKE position until engine runs
smoothly, then fully into RUN position. If
engine falters, move choke back to 1/2-
CHOKE
smoothly, then to RUN position.
NOTE: If engine fires, but does not continue to
run, move choke lever to Full CHOKE and
repeat starting instructions.
IMPORTANT NOTE: Do not overload gener-
ator or individual panel receptacles. These
outlets are overload protected with push-
to-reset circuit breakers. If amperage rat-
(000183)
ing of any circuit breaker is exceeded, that
breaker opens and electrical output to that
receptacle is lost. Read
Limits

Generator Shut Down

(000136)
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. Shut off all loads and unplug electrical
loads from generator panel receptacles.
2. Let engine run at no-load for several min-
utes to stabilize internal temperatures of
engine and generator.
3. Move RUN/STOP switch to STOP.
B
4. Close fuel valve.
NOTE: Under normal conditions, close fuel
valve and allow generator to run carburetor
bowl out of fuel. For emergencies, switch to
D
STOP.
008044
C
Figure 3-3.Choke Position
Figure
3-2. Firmly grasp recoil handle
position
until
carefully.
CAUTION
Owner's Manual for Portable Generator
000209
engine
runs
Know Generator
(000136)

Publicité