Warning: in closing position for all-glass wings, without
gaskets, leave at least 10 mm to avoid contact between
glass wings.
3.5 GUIDES AT FLOOR INSTALLATION
For guides at floor use only antifriction materials such as PVC,
NYLON, TEFLON. It is preferable that the length of the guide
should not be greater than the overlap between the mobile and
fixed wing, and that it not enter the passage space. The guide
slide on the floor must be smooth for the entire length of the
wing.
(KP515AB) Guide for framed door supplied by us: cut to re-
quired.
(KP369) Guide for glass door supplied by us.
KP515AB
3.6 BELT TIGHTNESS
-
-
-
-
-
3.7 INSTALLATION OF LOCKING DEVICE
-
-
-
-
KP369
15
Loosen screws [F] and tighten screw [G] until maximum
extension of the spring.
Loosen the screws that attach the return unit to the
guide.
Pull the belt and return pulley until tight, then secure to the
profile.
Loosen screw [G] until the spring has reached a compres-
sion of 22 mm for transom length (LT) <2600 or 20 mm for
cover length (LT) ≥2600.
Lock the setting with screws [F].
Put the wings in closed position.
Secure the lock to the profile.
Center the point of contact between [N] and locking bracket
[P] and manually check the correct operation of the locking
device.
Lightly lubricate pin [N] and the slanted part of bracket
[P].