Use Concentric Reducer
to mimimize friction losses.
Discharge pipe diameter at
least one nominal pipe size
larger than discharge opening
in pump.
Align piping to
minimize flange
stress.
• Use pipe, tubing or reinforced hose to make dis-
charge connection. Material selected must have
sufficient strength for operating pressures.
• Discharge pipe should be sized so that flow velocity
is below 8 feet per second.
• Use ONLY non-slamming check valves to prevent
hydraulic shock (water hammer).
• Use gate, ball, or butterfly valve for isolation. Valve
should be full open during operation.
• Maintain proper pipe size throughout discharge
system, using as few elbows and tees as possible to
keep friction loss to a minimum.
• Install pressure gauge after reducer as shown to
check operating pressure or shut-off head.
Page 12
Installation

Discharge Connection

Expansion joint with tie
rods where needed.
Isolation
Valve
Pressure
Gauge
Support piping
as required
Recommended
This view shows discharge
fittings typical of pump with
flooded suction.
This view shows discharge fittings
typical of pump with suction lift.
Isolation valve to
permit servicing of
check valve or pump.
This fitting may be used to
check shut-off head.
Non-Slam or
spring loaded
check valve.
Discharge
Priming
5781 0208
Valve
BE839