Discharge Pipe And Pressure Tank Connections; Standard Tank Connection - Pentair MYERS MPN Serie Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Discharge Pipe and Pressure Tank Connections

PRE-CHARGE TANk CONNECTION
(FIGURE 4)
Step 1. Install two tees in the pump discharge port (see
Figure 4). The pipe size must be at least as large
as the discharge port.
To Household
Water System
Pressure
Switch
Figure 4: Pre-charged Tank Connections
Step 2. Run a pipe or reinforced hose from one arm of
the first tee to the port on the pre-charged tank.
Step 3. Connect the other end of the discharge tee to
your plumbing system.
Step 4. Check the pre-charge of air in the tank with an
ordinary tire gauge. The pre-charge should be 2
PSI less than the cut-in setting of the pump's pres-
sure switch. The pre-charge is measured when
there is no water pressure in the tank. Your new
pump has a 30/50 PSI switch, so adjust the tank
pre-charge pressure to 28 PSI.*
Congratulations! You have just completed the
tank connection for your jet pump.
Please go to Pages 7 and 8 for electrical hookup.
Pump Priming
Tee and Plug
From
Well
1864 0205 FN

STANDARD TANk CONNECTION

(FIGURE 5)
Step 1. Install one tee in the pump discharge port (see
Figure 5).
To Household
Water System
Pump
Priming Tee
and Plug
Pressure
Switch
Figure 5: Standard Tank Connections
Step 2. Run a pipe from the pump discharge port to the
inlet port of your tank. The pipe size must be at
least as large as the discharge port.
Step 3. Remove the 1/8" NPT pipe plug from the pump Air
Volume Control (AVC) port (see Figure 5). Run tub-
ing from the pump's AVC port (see Figure 5) to the
port on the AVC mounted on the tank. See instruc-
tions provided with tank and AVC for details.
AVC port location will vary, depending on your
pump model (see exploded views, Pages 10-11).
Congratulations! You have just completed the
tank connection for your jet pump.
Please go to Pages 7 and 8 for electrical hookup.
Sealing Pipe Joints
Use only PTFE pipe thread sealant tape for making
all threaded connections to the pump itself. Do not
use pipe joint compounds on plastic pumps: they
can react with the plastic in pump components.
Make sure that all pipe joints in the suction pipe are
air tight as well as water tight. If the suction pipe
can suck air, the pump will not be able to pull water
from the well.
Air Volume
Control
Air Volume
Control Tube
From
Well
1865 0795FN
6