When to add fuel
CAUTION: HEATING MALFUNCTIONS
When adding too much fuel to the stove (overload), the controller fails or the LED
shows errors:
► Keep the firebox door closed.
► Never extinguish the burn-off with water.
► Allow the fire to burn out controlled.
The iQ technology will notify when to add fuel.
To minimise emissions, fuel should always be added at the optimal time:
LED
"occasional flashing"
"flashing speed increasing"
"steady light"
"off"

Adding fuel

Once the LED starts flashing, fuel can be added:
► Open the firebox door.
► Add two logs (
) with a total weight of 1.4 kg in the middle
4
of the firebox (face forward).
► Keep approx. 5 cm from the firebox glass (Fig. 6).
9 Close the firebox door.
When opening the firebox door the fuel indicator will extinguish and the controller
automatically changes the air slider to the optimal position.
NOTE: AMOUNT TO ADD
When adding fuel, never fully cover the firebed (risk of deflagration):
► When adding fuel, never add more than max. 1.8 kg of fuel.
INFO: COMBUSTION AIR OPENINGS
Inside the combustion chamber are combustion air openings (Fig. 18) which supply the
stove with rear wall air. Blocking these openings causes high emissions:
► Never block these openings with fuel!
► Observe the max. fill height of 20 cm.
Operating mode
Optimal time for adding wood
Fuel can still be added
Small logs can still be added
(deviation from optimal operating state)
Fuel cannot be added without aids
ALLOW STOVE TO GO OUT OR RELIGHT
Stopping the fire
Do not add fuel in order to stop the fire.
The air flaps will automatically close and the LED indicator will extinguish.
Faulty operating states
The LED shows the following errors:
LED
fast flashing
fast flashing
CAUTION: FAULTY OPERATING STATES
The stove can only be operated, if there are no errors shown by the controller and the
status light of the control panel lights up blue:
► Do not operate your stove, if errors are indicated by the LED.
► Contact HASE authorised dealer.
WARNING: CONTROLLER FAILURE
If the controller fails during use, proceed as follows:
► Do not add fuel.
► Allow the fire to burn out controlled.
► Contact HASE authorised dealer.
Maintenance
Fig. 6
MAINTENANCE POINT
Firebox glass
Surfaces
Control panel
Firebox door seal
Ash drawer seal
Fire grate
Ash drawer
Firebricks
Ash compartment
Firebricks
Flue pipe
Door mechanism
Chimney
Baffle plate
Temperature sensor
Catalytic combustors
****
Catalytic combustors
****
*If damaged and there are obvious leaks.
**Always vacuum with an industrial vacuum with ash separator.
***Included in the starter kit and available from your HASE authorised dealer.
****Replace catalytic combustor after 2,000 hours of operation.
R1_12/2022
Error
Temperature sensor
Power units
ITEM
WITH WHAT?
Clean
Paper towel
Clean
Paper towel
Clean
Cloth
Check/replace
New seal
Check/replace
New seal
Sweep/vacuum**
Broom/ash vacuum
Empty/vacuum**
Broom/ash vacuum
Sweep/vacuum**
Broom/ash vacuum
Vacuum**
Ash vacuum
Check
Eyes
Check/sweep
Broom
Grease
Speciality grease***
Have cleaned
Chimney sweep
Clean flue gas path
Brush
Brush
Brush
Brush
Brush
Vacuum, wash out,
Clean
blow out
www.hase.de
Fig. 7
INTERVAL
as required
as required
as required
as required*
as required*
Daily
Daily
Monthly
Monthly
Annually
Annually
Annually
Annually
Annually
Annually
After 50 hours
of operation
After 200 hours
of operation