Quick Installation

1
Insert a user-supplied power cord
(with country-specific plug) into the
UPS System's IEC-320-C20 AC Input
Receptacle. Plug the cord into an AC
wall outlet.
NOTE! After you plug the UPS into a live AC outlet,
the UPS (in "Standby" mode) will automatically
charge its batteries, but will not supply power to its
outlets until it is turned ON.
2
Using the jumper cords supplied with
the UPS, plug your equipment into
the UPS.*
* Order additional jumper cords from Tripp Lite.
Call (773) 869-1234; order part # P004-006.
Your UPS is designed to support only comput-
er equipment. You will overload the UPS if the
total VA ratings for all the equipment you con-
nect exceeds the UPS's Output Capacity (see
Specifications). To find your equipment's VA rat-
ings, look on their nameplates. If the equipment
is listed in amps, multiply the number of amps by
230 to determine VA. (Example: 1 amp × 230 =
230 VA). If you are unsure if you have overloaded
the UPS's outlets, see "OUTPUT LOAD LEVEL" LED
description.
3
Turn the UPS ON.
Press and hold the "ON/OFF/STANDBY" button
for one second. The alarm will beep once after
one second has passed. Release the button.
18-08-322-932245.indb 3
1
Shown: SMARTINT2200VS
2
3
3
5/3/2019 1:44:52 PM