CAME BXV04AGS Instructions De Montage page 79

Masquer les pouces Voir aussi pour BXV04AGS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

BUS device status
Show the status of all devices that can be connected to the BUS and managed by the firmware in use.
Key
<n> is the device number.
Information
Manoeuvre counter
View the number of total or partial operator manoeuvres (after maintenance).
The number of manoeuvres is the number shown multiplied by 100.
Information
Configure maintenance
Set the number of manoeuvres the operator can perform before a maintenance warning signal is generated.
The warning is displayed as an [Maintenance required] message and signalled by 3 + 3 flashes every hour on the device connected to the 10-5 output.
Information
Maintenance reset
Reset the number of partial manoeuvres.
Information
Errors list
View the last 8 errors detected. The error list can be deleted.
Information
BUS device status
Manoeuvre counter
Maintenance conf.
Maintenance reset
Errors list
Photocell BUS <n>
<n> from 1 to 8
The status shown may be:
ok
not communicating
safety device active
BUS selector <n>
<n> from 1 to 7
The status shown may be:
ok
not communicating
BUS flashing beacon <n>
<n> from 1 to 2
The status shown may be:
ok
not communicating
Total manoeuvres
Manoeuvres performed since the operator was installed.
Partial manoeuvres
Manoeuvres carried out after the last maintenance.
Deactivated (Default)
from 1 x100 to 500 x100
Confirm? NO
Confirm? YES
Use the arrows to scroll through the list.
To cancel the error list, select [Delete errors]
Press ENTER to confirm.