RIO PH T1 and RIO PH T2
Associate one of the available functions with a wireless safety device.
The function only appears if the RIO CONN interface board is present.
Configuration >
RIO safety devices
Photocell BUS <n>
Associate a function with the photocell BUS <n> input.
<n> is between 1 and 8 and corresponds to the address set on the photocell dip-switch
The function only appears if there is a BUS photocell connected.
Configuration >
BUS safety devices
Command 2-7
Associate a command to the connected device on 2-7.
Configuration >
Command inputs
Hold-to-run
With the function active, the operator stops moving (opening or closing) when the control device is released.
When the function is active, it excludes all other control devices.
Configuration >

Functions

B1-B2 output
Configure the contact.
Configuration >
Functions
Removing obstacles
If an obstacle is detected by the sensitive edge or by the amperometric sensor on the electronic board, movement is inverted to create a space sufficient to clear
the obstacle.
If this function is deactivated, the motion is inverted until the limit-switch is reached.
Configuration >
Functions
RIO PH T1
RIO PH T2
BUS Photocell 1
Photocell BUS 2
Photocell BUS 3
Photocell BUS 4
Photocell BUS 5
Photocell BUS 6
Photocell BUS 7
Photocell BUS 8
Command 2-7
Hold-to-run
B1-B2 output
Removing obstacles
Deactivated (Default)
P1 = Reopen while closing.
P2 = Reclose while opening.
P3 = Partial stop. Only with [Automatic close] activated.
P4 = Obstacle standby.
P13 = Reopening during closure with immediate stop once the obstacle has been
removed, even with the gate not in motion.
Deactivated (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic close] activated.
C4 = Obstacle standby (photocells)
C13 = Reopen while closing, with immediate stop once the obstruction has been
removed, even if the gate is not in motion
Opening = Open command
Closing = Close command
Step-by-step (Default)
Sequential
Deactivated (Default)
On
Bistable
Monostable: on from 1 to 180 seconds (Default 1)
Deactivated (Default)
On