Les langues disponibles

Automatic closure
Set the time before automatic closure, once the opening travel end point has been reached or once the photocells have caused a partial stop [C3].
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a complete stop, during a power outage or if
there is an error.
Configuration >
Times
Automatic closing after partial opening
Set the time before automatic closure after a partial opening command has been performed or after the photocells have caused a partial stop [C3].
The function does not work if any of the safety devices are triggered when an obstacle is detected, after a complete stop, during a power outage or if
there is an error.
Configuration >
Times
Passage-open warning light
It signals the gate status.
The device is connected to output/terminal 5.
Configuration >
Manage lights
Light E1
Choose the operating mode for the lighting device connected to output E1.
Configuration >
Manage lights
Courtesy time
Define how many seconds the additional light (set up as courtesy light) stays on after an opening or closing manoeuvre.
Configuration >
Manage lights
Pre-flashing time
Adjust the time for which the beacon is activated before each manoeuvre.
Configuration >
Manage lights
<Mode> BUS flashing beacon
Choose the operating mode for the lights connected to the BUS connector.
The function only appears if there is a BUS flashing beacon connected.
Configuration >
Manage lights >
BUS flashing beacon
Automatic close
Automatic partial close
Passage-open warning light
Light E1
Courtesy time
Pre-flashing time
Mode
Deactivated (Default)
From 1 to 180 seconds
Off
1 to 180 seconds (Default 10 seconds)
Warning light on (Default) - The warning light stays on when the gate is moving or
open.
Warning light flashing - The warning light flashes every half second when the gate is
opening and stays on when the gate is open. The light flashes every second when the
gate is closing, and remains off when the gate is closed.
Flashing beacon (Default)
Cycle lamp - The lamp stays on during the manoeuvre.
The light remains off if an automatic closing time is not set.
Courtesy light - The light switches on when a manoeuvre starts and remains on once
the manoeuvre has finished, for the time set under the [Courtesy time] function.
60 to 180 seconds (Default 60 seconds)
Deactivated (Default)
1 to 10 seconds
Flashing beacon (Default). The light flashes during opening and closing.
Cycle flashing beacon. The light flashes during opening and closing and remains on
during the countdown before automatic closure.