Opening slowdown point
Set the percentage of the total travel to be used for slowdown during gate opening.
During travel calibration, the opening slowdown point is automatically set to allow for a slowing space of 60 cm.
Configuration >
Gate travel settings
Closing slowdown point
Set the percentage of the total travel to be used for slowdown during gate closing.
During travel calibration, the closing slowdown point is automatically set to allow for a slowing space of 60 cm.
Configuration >
Gate travel settings
Impact test
Activate/deactivate test mode for impact tests. With the function on, the operator does not signal errors connected to obstacle detection after more than one
consecutive impact.
Pre-set the travel parameters, according to the gate weight, to use for impact tests.
Test mode is deactivated automatically after 1 hour.
With the function on, the display shows the
Configuration >
Gate travel settings
Total stop
Activate or deactivate input 2-1. If it is activated, the input is used as a normally closed contact.
If the input is active, this excludes all commands, including any automatic closing.
Configuration >
Wired safety devices
Opening slowdown point
Closing slowdown point
icon.
Impact test
Total stop
2% to 60% (Default 25%)
2% to 60% (Default 25%)
Activate mode
Deactivate mode
Leaf weight
Only versions BXV04AGE and BXV06AGE.
Select the gate weight value closest to the real weight:
200 (Default)/300/400 kg for BXV04AGE
400 (Default)/500/600 kg for BXV06AGE
Apply pre-set
Configure the travel parameters according to the set leaf weight.
Deactivated (Default)
On