<Pre-flashing colour> BUS flashing beacon
On the BUS flashing beacon, set the flash colour for before opening and closing manoeuvres (pre-flash).
The function only appears if there is a BUS flashing beacon connected.
b40 >
<Signal error> BUS flashing beacon
Set the colour of the BUS flashing beacon in the event of an error signal.
The function only appears if there is a BUS flashing beacon connected.
b40 >
Signal maintenance
Set the colour on enabled BUS devices (flashing beacons and selectors) to signal that maintenance needs to be performed when the number set under function
[F58] is reached.
The number of manoeuvres must be set under function [F58].
With the function activated, after the set number of manoeuvres has been reached, each subsequent manoeuvre will cause the BUS devices (selectors
and flashing beacons) to flash.
The function only appears if there is a BUS flashing beacon or a BUS selector connected.
b43 >
When using a CAME KEY device, always update the board firmware to the latest version.
L4
L5
1 = White
2 = Yellow
3 = Orange
4 = Red
5 = Purple
6 = Blue
7 = Light blue
8 = Green
0 = Deactivated
1 = White
2 = Yellow
3 = Orange
4 = Red
5 = Purple
6 = Blue
7 = Light blue
8 = Green
0 =Deactivated (Default)
1 = White
2 = Yellow
3 = Orange
4 = Red
5 = Purple
6 = Blue
7 = Light blue
8 = Green