CX input
Associate a function with the CX input.
F2
CY input
Associate a function with the CY input.
F3
CZ input
Associate a function with the CZ input.
F4
Safety devices test
Check that the photocells connected to the inputs are operating correctly, after each opening and closing command.
F5
OFF (Default)
C1 = Reopen while closing (photocells)
C4 = Obstacle standby (photocells)
C5 = Immediate closure at the travel end during opening
C7 = Reopen while closing (sensitive edges)
C9 = Immediate closure at the travel end during opening with obstacle standby during closure
C10 = Immediate closure during opening with obstacle standby during closure (NO contact)
C11 = Immediate closure during opening with obstacle standby during closure (NC contact)
C13 = Reopening during closure with immediate stop once the obstacle has been removed, even with boom not in
movement
r7 = Reopen while closing (sensitive edges with 8K2 resistor)
OFF (Default)
C1 = Reopen while closing (photocells)
C4 = Obstacle standby (photocells)
C5 = Immediate closure at the travel end during opening
C7 = Reopen while closing (sensitive edges)
C9 = Immediate closure at the travel end during opening with obstacle standby during closure
C10 = Immediate closure during opening with obstacle standby during closure (NO contact)
C11 = Immediate closure during opening with obstacle standby during closure (NC contact)
C13 = Reopening during closure with immediate stop once the obstacle has been removed, even with boom not in
movement
r7 = Reopen while closing (sensitive edges with 8K2 resistor)
OFF (Default)
C1 = Reopen while closing (photocells)
C4 = Obstacle standby (photocells)
C5 = Immediate closure at the travel end during opening
C7 = Reopen while closing (sensitive edges)
C9 = Immediate closure at the travel end during opening with obstacle standby during closure
C10 = Immediate closure during opening with obstacle standby during closure (NO contact)
C11 = Immediate closure during opening with obstacle standby during closure (NC contact)
C13 = Reopening during closure with immediate stop once the obstacle has been removed, even with boom not in
movement
r7 = Reopen while closing (sensitive edges with 8K2 resistor)
OFF (Default)
1 = CX
2 = CY
3 = CX+CY
4 = CZ
5 = CX+CZ
6 = CY+CZ
7 = CX+CY+CZ