Manoeuvre counter
View the number of total or partial operator manoeuvres (after maintenance).
The number of manoeuvres is the number shown multiplied by 1000.
A5
FW version
Display the firmware version number.
H1
Enable password
Set a 3-digit password. The password will be requested to anyone who wants to access the main menu.
Remove the password that protects access to the main menu.
H3
Forgotten password
If you forget your password, follow the procedure below.
Disconnect the control board from the power supply.
Press and hold the < and > buttons, then reconnect the control board to the power supply.
Continue to press and hold the < > buttons until [ON/OFF] is displayed.
Select [ON].
Press ENTER to confirm.
When you reset the control board, all saved users, set times and calibration operations are deleted.
BUS device status
All devices that can be connected to the BUS and managed by the firmware in use.
Key
b = BUS photocells
d = BUS selector
L = BUS flashing beacon
<n> is the device number.
<x> is the device status.
H4
Tot = total manoeuvres
Manoeuvres performed since the operator was installed.
Par = partial manoeuvres
Under the [Par] parameter, press the ENTER key to reset the number of partial manoeuvres. [Clr] will appear on the
screen to confirm deletion.
ON
Use the arrows and the Enter button to dial the desired code.
b<n>.<x>
<n> from 1 to 8
d<n>.<x>
<n> from 1 to 7
L<n>.<x>
<n> from 1 to 2
OFF
Press ENTER to confirm deletion.
<x> device status
|| = Conflicting address
o = Working
c = Working with alarm signal
F = Device fault
- = No communication or not present