FCA FCC warnings
Configure the method with which the FCA and FCC outputs report the boom status.
F70
Opening counter
With the function active, you can send a series of opening commands corresponding to the number of vehicles which have to be authorised to pass through the
gate. The function can only be operated by control devices connected to the contact 2-3. The magnetic contact, to which the loop that counts vehicles in transit is
connected, is connected to an input. This input must be programmed to operate in C5/C9/C10 mode. At the end of the count the passage is closed.
F75
Emergency battery operation
Emergency function in the event of a power outage. Batteries required.
F93
New user
Register up to a maximum of 250 users and assign a function to each one.
The operation can be carried out by using a transmitter or another control device. The boards that manage the control devices (AF - R700 - R800) must
be inserted into the connectors.
U1
Remove user
Remove one of the registered users.
U2
OFF (Default)
1 = Impulse
When the boom reaches the travel end point (while opening or closing), the FCA-CM1 or FCC-CM2 contact closes for one
second.
2 = Steady
When the boom reaches the travel end point (while opening or closing), the FCA-CM1 or FCC-CM2 contact closes and
remains closed.
3 = Custom
The FCA-CM1 contact is closed with the boom in the open travel end position and during the opening manoeuvre. The FCC-
CM2 contact is closed with the boom in the closed travel end position and during the closing manoeuvre.
OFF (Default)
ON
OFF (Default)
1 = Immediate opening
In the event of a power outage, the operator runs an opening command within 1 minute and all other commands are blocked
until power is restored.
1 = Step-by-step
2 = Sequential
3 = Open
4 = Partial opening
When the barrier is in [Paired] mode, the [Partial Opening] command opens the Master barrier.
Choose the function to be assigned to the user.
Press ENTER to confirm.
The free position in the memory is shown intermittently for a maximum of 10 seconds. During this phase, send the code
from the control device.
Repeat the procedure to add other users.
OFF (Default)
ON
No. 1 > 250
Use the arrows to choose the number associated with the user you want to remove.
Alternatively, the control device associated with the user you want to remove can be activated.
Press ENTER to confirm.
"CLr" will appear to confirm deletion.