Les langues disponibles

Command and control devices
1
STOP button (NC contact)
This stops the boom and excludes automatic closing. Use a control device to resume movement.
If the contact is not used, it must be deactivated during programming.
2
Control device (NO contact)
OPEN ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during OPENING.
Control device (NO contact)
3
PARTIAL OPENING function
The contact must only be used for operators working in paired mode.
4
Control device (NO contact)
CLOSE ONLY function
When the [HOLD-TO-RUN] function is active, the control device must be connected during CLOSING.
5
Control device (NO contact)
OPEN-CLOSE function
6
Card reader
Insert the R700 card into the corresponding connector.
Transponder selector switch
7
Insert the R700 card into the corresponding connector.
8
Keypad selector
Insert the R800 card into the corresponding connector.
9
Antenna with RG58 cable
Insert the AF card into the corresponding connector for remote control with transmitter.
S 1
2
3 3P 4
5
7
2 CX CY CZ
S1 GND
A
B