AC/DC TRUE RMS CLAMP METERAC/DC
2)Press the jaw trigger and clamp around, fully enclosing a single
conductor. Do not allow a gap between the two halves of the jaw.
Refer to the diagram at right for the correct way
to enclose a single conductor
3) Read the ACA value on the LCD
DC Current Measurements
1) Set the Function switch to the ACA range
2) Press the DCA ZERO key to null the meter
display
3) Press the trigger to open the current sense
jaw
4) Fully enclose the conductor to be measured. Do not allow a gap
between the two halves of the jaw
5) Read the DCA value on the LCD
AC/DC Voltage Measurements
1. Insert the black test lead into the negative COM terminal and
the red test lead into the positive V terminal
2. Set the function switch to the V position
3. Press AC/DC button 2 Sec, select AC/DC
4. Connect the test leads in parallel to the circuit under test
5. Read the voltage measurement on the LCD display
Resistance and Continuity Measurements
1. Insert the black test lead into the negative COM terminal and
the red test lead into the positive terminal
2. Touch the test probe tips across the circuit or component under
test. It is best to disconnect on side of the device under test so the
rest of the circuit will not interfere with the resistance reading
3. For Resistance tests, read the resistance on the LCD display &
if the resisitance is <300Ω, a tone will sound.
Non-Contact AC Voltage Measurements