FASTER ICE – Issue 00
Command 99 View error events:
This command displays the last 20 error events; to go from one display to another press the ENTER key. At
the end of the display, the system asks the user to confirm the clearing of all the data. Press ENTER to
confirm or ESC to leave the records as they are.
ERROR
SUB-CODE
CODE
01
Number selection code Motor blocked (the spiral does not rotate)
02
Number selection code The spiral does not complete the rotation
05
Number selection code Motor disconnected
05
(*) 12
09
Number selection code Possible microswitch defect or spiral motor wiring defect
09
(*) 12
10
(*) 38 - 39
11
(*) 38 - 39
16
(*) 33 - 38 - 39
17
(*) 38 - 39
18
(*) 38 - 39
30
(*) 38 - 39
31
(*) 38 - 39
32÷38
(*) 38 - 39
39
(*) 38 - 39
51
(*) 38 - 39
55
61
Number selection code Motor blocked (the spiral does not rotate) SLAVE A
62
Number selection code The spiral does not complete the rotation SLAVE A
65
Number selection code Motor disconnected SLAVE A
69
Number selection code Possible microswitch defect or spiral motor wiring defect SLAVE A
91
Number selection code Selections not reset.
93
(
) Key:
*
12 = Insulating door motor
33 = Photocells
38 = Spirali Master
39 = Spirali Slave
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: info@fas.it
Insulating door motor disconnected
Probable defect of the microswitch or of the motor of the insulating
door
Internal temperature feeler faulty
Evaporator probe faulty
Error communication with peripheral (a board for the electric panel)
Communication break during sale cycle without credit collection
Communication break during sale cycle with credit collection
Fridge safety has intervened
Photocell test error .
Photocell calibration error
photocell safety
Interruption of peripheral connection at the beginning of the sale
cycle.
/
Payment system out of service.
/
Fridge safety has intervened
FAILURE