Commands 66-67 Internal temperature and evaporator temperature display:
The value set at these commands determines the information shown on the second line of the display (see
table). As default, the clock is displayed.
Command 66
0
1
0
1
* Command 66 displays the internal temperature of any SLAVE machine connected to the master machine.
In this case the temperature of the master is indicated by TM, whereas the temperature of the slave is
indicated by TA.
Furthermore, only during the programming phase, command 67 displays the internal temperature and the
evaporator temperature of any SLAVE machine connected to this machine.
E
Command 68 Setting displayed currency description :
N
The command allows the operator to set the desired currency. 4 characters are available and they are
G
entered using the same method as described for Command 95.
L
I
Command 69 Chooses functioning mode of the coin mechanism:
S
This command chooses the type and mode of functioning of the coin mechanism. The parameter can
H
assume the following values:
0
System EXECUTIVE with prices controlled in the machine (see relevant paragraph).
1
System EXECUTIVE in PRICE HOLDING mode (i.e. prices programmed in the coin mechanism). In
this case, the prices programmed at command 03 and those programmed in the coin mechanism must be
the same (see relevant paragraph). Alternatively you can set the "Price-Display" parameter. If enabled, the
vending machine will utilize exclusively the information on the price value deriving from the payment system,
that is, it will not be necessary to fill in the price tables (Commands 03 and 04); simply set only Command 05
(see relevant paragraph).
4
System BDV 001 (see paragraph using the coin mechanism BDV)
5
Payment system MDB (see paragraph on using the MDB payment system).
Command 70 Buzzer operation option:
By setting this command at zero the buzzer is disconnected during machine operation.
Command 73 Enabling the photoelectric cells:
This command should be set at 1 only if the photoelectric cell system is installed. Its function is to
enable=1/disable=0 this device. Note: This setting is valid for both machines (MASTER and SLAVE).
Set the command at 1 (photocells enabled), to automatically access the menu which allows this function to be
disabled if necessary for the desired selections (delivery without photocell control). To disable the option
corresponding to one or more selections, simply key in the selection number and then set the value at zero.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set.
Command 74 Photocell test:
This command is used to test that the photocells are functioning correctly. A test procedure is started
automatically, then at the end of the procedure, if there are no problems a single value appears which
corresponds to the magnitude of the incoming signal. If there is a problem with the functioning, a second
value appears on the display which refers to the problem. See the table for Command 99 for this second
value.
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: info@fas.it
Command 67
Displayed value
0
Displays clock
0
Displays internal temperature *
1
Displays internal temperature + evaporator temperature
1
Displays clock + internal temperature
FASTER ICE – Issue 00