FAS International FASTER ICE Mode D'emploi page 68

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

24
Command 79 Motorized insulating door:
In order to ensure that the door is not blocked by the low temperature it is possible to set a time after which a
door movement cycle is carried out. The default value is 180 min and it can be programmed from 1 min to
360 min.
Then the system asks you to program the extra-stroke time of the motorized insulating door which
guarantees tightness when it presses on the seal. The parameter can be set from 0 to 20. Default value = 12.
On the other hand, when you enter the second programming level, you can run the door opening/closing test.
The display shows whether the door is in the open position (door open = 0) or in the closed position (door
closed = 1).
Selection push-button panel
Button
1
Button
2
Button
8
Button
9
E
N
Command 80 Cloning:
G
This command makes it possible to transfer all the parameters of the vending machine to a "Program Key",
L
to program same model machines. When you enter the command "Write Clone Key" appears on the display.
I
Then, enter the "Program Key" and press the ENTER key. "Data Writing...*" appears on the screen while the
S
data is being transferred to the key. Once the data transfer operation is completed, the machine returns to
H
the programming mode.
Caution: DO NOT enter the key before entering the programming mode, otherwise the vending machine will
fetch the data existing in the key.
Command 81 Fetch vend data:
This command makes it possible to transfer all the EVA-DTS data to a "Program Key". This data can be
extracted using special software (VMC configurator). The maximum number of possible registrations is 100.
Attention: if the key is not recognised as a data key, at the first registration the user will be asked to confirm
the complete deletion of the existing data.
Command 85 Display of checksum and main and power board software version.
Command 90 Selecting the AUDIT / telemetry enabling protocol:
The control card has a jack RS232.
The connector I/O is a 9 poles with male container in which the following pins are used:
The transmission happens according to the following specifications:
The transfer of the data is ruled by a control signal DTR (active high) given by the device to fetch data.
The data fetch from the machine happens as follows:
1.
Connection of the device to fetch data to the jack RS232.
2.
Press pushbutton data sending.
3.
After the transmission of data the request to disconnect the device is displayed.
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: info@fas.it
Door opening
Door closing
Door opening with button pressed
Door closing with button pressed
- Pin 2
Tx
-9600 baud
- 8 bit of data
- Pin 7
DTR
- Pin 5
- no parity
FASTER ICE – Issue 00
Ground

Publicité

Table des Matières
loading

Table des Matières