Oceanic OCEACLIM140W1 Guide D'utilisation page 44

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• This appliance contains 226g of R290
refrigerant gas.
• R290 is a refrigerant gas that complies with
European environmental directives. Do not
pierce any part of the refrigerant circuit.
• If the appliance is installed, used, or stored in
a non-ventilated area, the room must be
designed to prevent the accumulation of
refrigerant leaks that could result in a fire or
explosion hazard due to refrigerant ignition.
caused by electric heaters, stoves, or other
sources of ignition.
• The device must be stored in such a way as
to prevent mechanical failure.
• Those who operate or work on the refrigerant
circuit must have the appropriate certification
issued by an accredited body that guarantees
proficiency in the handling of refrigerants
according to a specific assessment recognized
by industry associations.
• Repairs must be made according to the
manufacturer's recommendations.
• Maintenance and repairs that require the
assistance of other qualified personnel must be
performed under the supervision of a person
specified in the use of flammable refrigerants.
44

Publicité

Chapitres

Table des Matières
loading

Table des Matières