9. 3. 1. 1 
DISMANTLING B RA CKETS SIZES 25,35 A ND 45 
 
 
1.  Mark  the  position  of  the  parts  in  relation  to  each  other  with  a 
color pen or a scribing point. 
2. Remove the hexagonal screws 90.10. 
3. Withdraw the back pull out unit from the volute casing 10.20. 
 
4. Remove flat gasket 40.00. 
5. Remove screws 90.13 and remove protective screen. 
6. Loosen impeller nut 92.20. 
7. Remove impeller 23.00 and key 94.01. 
 
Design with stuffing box 
1. Remove the screws 91.40 and remove the casing cover 16.10. 
2. Remove nuts 92.01 and stud bolts 90.21. 
3.  Loosen  screws  90.23  and  remove  stuffing  box  45.10  and  gland 
45.20 with the pressure ring 45.70. 
4. Tear out packing rings 46.10 and remove lantern ring 45.80. 
5. Slide out shaft sleeve 52.40. 
 
Repacking: 
When repacking, the worn packing rings and the lantern ring should 
be  removed  carefully  from  the  shaft  seal  chamber.  The  shaft  and 
shaft  sleeve  must  not  be  damaged.  Otherwise  a  perfect  sealing 
cannot  be  guaranteed  anymore  and  the  shaft  sleeve  should  be 
replaced. If the pump is installed, cut packing rings diagonally, bend 
them in a spiral shape, position them on the pump shaft and bend 
them  carefully  into  a  ring  form.  Push  the  packing  rings  and  the 
lantern ring using the gland into the shaft sealing chamber. The cut 
joints should be staggered by 180°. Tighten the gland adjusting nuts 
steadily  until  resistance  is  felt  when  rotating  the  pump  shaft  by 
hand.  Remove  the  gland  again  and  fasten  the  nuts  slightly.  If  the 
pump  is  dismantled,  it  is  useful  to  push  the  packing  rings  in  the 
delivered condition, that means closed over the shaft sleeve. 
All manuals and user guides at all-guides.com
 
 
 
17 
Design with mechanical seal : 
1. Slide out the spacer ring 50.40. 
2. Remove the rotating part of the mechanical seal 43.30. 
3. Remove the screws 91.40 and remove the casing cover 16.10. 
 
Design with quench : 
Remove cover 16.50, O‐ring 41.23 and lip seal 42.11. 
Design with external heating 
Remove cover 16.50, O‐rings 41.22 and 41.23. 
4.  Push  out  the  static  part  of  the  mechanical  seal  43.30  and  pin 
56.10 if necessary. 