INSTALLATION (INSTALLER)
Technical information
• The installation, the adjustments, conversions and maintenance of the appliance
must only be carried out by a qualified technician or installer. The manufacturer
cannot be held responsible for any damage to persons or things deriving from an
incorrect installation of the appliance.
• The safety and adjustment devices of the appliances may, during their life, only be
modified by the manufacturer or duly authorised supplier.
• All-gas appliances can be installed as "Class 3" (fitted) in compliance with gas
standards only.
• Any side walls (one only – left or right) that overcome in height the work top, have
to be 50 mm far at least.
• The adhesive used to join the laminated plastic to the piece of furniture must be
able to withstand a temperature of at least 150 °C, so the laminated plastic will not
come unstuck.
• The installation of all-gas appliances must comply with the National Rules in force.
• This appliance is not connected to a flue for discharge of the combustion products.
Therefore, it must be connected in compliance with the above mentioned installation
rules. Particular attention must be paid to the instructions given below for ventilation
and aeration.
Ventilating the rooms
The room, where the appliance is installed, must be permanently ventilated so as to
guarantee correct functioning according to the National Rules in force. The quantity of
air needed is that required for a regular combustion of the gas and for the ventilation of
the room and whose volume must be no less than 20 m
direct through permanent openings in the walls (that go through to the outside) of the
room to be ventilated with a minimum cross free section of 100 cm
with the Flame Safety Device (FSD) on each burner (see figure 1). These openings must
be positioned so they cannot be ever obstructed. If the appliance is not fitted with the
Flame Safety Device (FSD) on each burner, the cross free section shall be not less than
200 cm
.
2
Indirect ventilation is also allowed by taking air from rooms adjacent to the one to be
ventilated, strictly complying with the prescriptions of the National Rules in force.
. The natural flow of air must be
3
for appliance fitted
2