Télécharger Imprimer la page

GM Racing GENIUS SPORT 30R Instructions D'utilisation page 15

Publicité

Les langues disponibles

Les langues disponibles

Functions
5. Reverse Power
Following by the start power system, the program will enter reverse power setting. This section offers
8 options. The motor will come up the corresponding tones as indicator. The following is the indication
with graphic reference.
5-1...0% Reverse Power
5-2...20% Reverse Power
5-3...40% Reverse Power
5-4...60% Reverse Power (Factory Default)
5-5...70% Reverse Power
5-6...80% Reverse Power
5-7...90% Reverse Power
5-8...100% Reverse Power
When intend to choose one of above options, simply position the throttle stick from neutral point to
maximum after the indication tone. The next step is to release the throttle stick back to the neutral
point to confirm. If there is no need to enter next set up section, you could simply shut down the
power. The selection was stored into the microprocessor when the throttle stick was in confirmation
position. If there is need to enter run mode set up section, simply wait for the next tone.
6. Run Mode
Following by the reverse power system, the program will enter run mode setting. This section offers 5
options. The motor will come up the corresponding tones as indicator. The following is the indication
with graphic reference.
6-1...Forward Only
6-2...2-Stage Reverse
6-3...2-Stage Reverse with Safe Brake(Factory Default) eeeeee-eee
6-4...1-Second Reverse
6-5...1-Second Reverse with Safe Brake
When intend to choose one of above options, simply position the throttle stick from neutral point to
maximum after the indication tone. The next step is to release the throttle stick back to the neutral
point to confirm. If there is no need to enter next set up section, you could simply shut down the
power. The selection was stored into the microprocessor when the throttle stick was in confirmation
position. If there is need to enter fuzzy motor timing set up section, simply wait for the next tone.
*Note 1 Safe Brake= When the motor forward on time, user wants to immediately change directions
of motor, the microprocessor will gives few pressure of brake till the motor stop, then the motor will
follow user's control.
7. Fuzzy Motor Timing
Following by the run mode, the system enters fuzzy motor timing set up section. In this section the
system offers 4 options, auto timing, soft timing, standard timing and hard timing. The motor will come
up the corresponding tones as indicator. The following is the indication with graphic reference.
7-1...Auto Motor Timing (Factory Default)
7-2...Soft Motor Timing
7-3...Standard Motor Timing
7-4...High Motor Timing
When intend to choose one of above options, simply position the throttle stick from neutral point to
maximum after the indication tone. The next step is to position the throttle stick back to the neutral
point to confirm. You could now simply shut down the power. The selection was stored into the
microprocessor when the throttle stick was in confirmation position. If there is need to enter battery
management system set up section, simply wait for the next tone.
eeeee-e
eeeee-ee
eeeee-eee
eeeee-eeee
eeeee-eeeee
eeeee-eeeeee
eeeee-eeeeeee
eeeee-eeeeeeee
eeeeee-e
eeeeee-ee
(Note1)
eeeeee-eeee
eeeeee-eeeee (Note 1)
eeeeeee-e
eeeeeee-ee
eeeeeee-eee
eeeeeee-eeee
Functions
15

Publicité

loading

Ce manuel est également adapté pour:

7161