Setting the node address

)
Note!
Use different node addresses for several networked inverters.
ƒ
The Lenze setting for the node address (node ID) has the value '4':
– link switch in position '0'
– right switch in position '4'
Switch the voltage supply of the inverter/communication module off and
ƒ
on again to activate changed settings.
Fig. 2
Setting the node address
Each node has to be assigned to a unique address (node ID).
ƒ Valid address range for slave (controlled node): 1 ... 239
ƒ The corresponding IP address of the communication module results from the setting
of the two rotary switches.
IP address: 192.168.100.<Node ID>
(Value Left Switch
EDK2191DB DE/EN/FR 2.0
16) )(Value Right Switch ) + Node Address
l
Commissioning
Setting the node address
7
2191EPL001B