SATA jet 100 B F RP/HVLP Mode D'emploi page 135

Masquer les pouces Voir aussi pour jet 100 B F RP/HVLP:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 195
Operating Instructions SATAjet 100 B F (RP / HVLP), B P
All manuals and user guides at all-guides.com
cause injuries. Always vent the hoses completely before they are loos-
ened.
Cleaning
■ Never use acidic or alkaline cleaning agents to clean the spray gun.
■ Never use cleaning agents based on halogenated hydrocarbons.
Point of use
■ Never use the spray gun in the vicinity of ignition sources, such as
naked flames, burning cigarettes or non-explosion-proof electrical
equipment.
■ Only use the spray gun in well ventilated rooms.
General
■ Never point the spray gun at human beings.
■ Comply with the local regulations for safety, accident prevention, occu-
pational health and safety and environmental protection.
■ Heed the accident prevention regulations.
3. Intended Use
The spray gun is used to apply paints, lacquers and other sprayable me-
dia on suitable substrates.
4. Description
The compressed air required for spraying is supplied at the compressed
air connection. Pull the trigger to the first pressure point to activate the
pre-air control. Continue pulling the trigger to pull the paint needle out of
the fluid tip: the material flows without pressure out of the fluid tip and is
atomised by the compressed air flowing out of the air cap.
5. Scope of Delivery
■ Spray gun with nozzle set B F RP / B F HVLP/ B P and gravity flow cup
■ Tool kit
■ CCS clips
■ Operating Instructions
Alternative version
■ Gravity flow cups made of PVC or aluminium with different capacities
After unpacking, check:
■ Spray gun damaged
■ Complete scope of supply
EN
135

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Jet 100 b p

Table des Matières